Running recon-all on data collected at 7T

See also: SubmillimeterRecon

Compared to 3T MPRAGE and MEMPRAGE scans collected at 7T have stronger intensity inhomogenity, which won't be fully corrected in the default recon-all. Therefore, to process 7T data we recommend the following steps:

1) Bias-correct your input images using SPM12's unified segmentation algorithm (Ashburner and Friston, 2005)

2) Run recon-all as usuall with your bias-corrected image as input. (If your 7T voxel size is less than 1mm3 and you would like to process it at native resolution, see SubmillimeterRecon page on how to run recon-all)

Recommended bias-correction parameters:

Bias FWHM = 18

Sampling distance = 2